C6-2 Zoning is a General Central Commercial Zoning District in NYC. In C6-2 you can build a variety of commercial building uses, community facilities and residential buildings.
The C6-2 Zoning District is a sub district of C6 Zoning in NYC. C6 is a general central zoning district with generally large buildings having retail, department stores, large offices, hotels, and residential uses. C6-2 Zoning is mapped in Manhattan, The Bronx, and Brooklyn.
C6-2 Zoning Districts:
- C6-2
- C6-2A
C6-2 Residential Equivalent:
- R8
C6-2 Zoning Regulations
C6-2 Residential Equivalent
Most Commercial Zoning districts have a Residential Equivalent. This equivalent is the Residential Zoning you would comply with when developing a residential building. The residential equivalent for C6-2 is R8 Zoning.
Mixed Use Building
You can develop a mixed use building with commercial and residential zoning. In this case you would apply the requirements of C6-2 and R8 in designing the building.
C6-2 Zoning Specifications
C6-2 Commercial Floor Area Ratio (FAR):
Floor Area Ratio determines the floor area that can be built on the property.
FAR = 6
The FAR is for Commercial Floor Area residential use usually differs.
Plaza Floor Area Bonus:
1 to 4 ratio plaza to building floor area bonus
You can build 4 additional square feet of building for every square foot of plaza. Plazas have specific requirements not all locations qualify.
Arcade Floor Area Bonus
1 to 2 ratio arcade to building floor area bonus
You can build 2 additional square feet of building for every square foot of arcade. Arcades have specific requirements not all locations qualify.
C6-2 Community Facility Floor area Ratio
FAR = 6.5
Sometimes the FAR is higher for community facilities as it is in this case.
Yard Requirements for Commercial Use in C6-2
Side Yards
Side Yards are not required, but if side yards are provided they must comply with the following:
At minimum 8 feet in width or
At minimum 5 feet in width with an average width of 8 feet.
Some special circumstances will require side yards.
Rear Yard
20 Foot rear yard required
C6-2 Height And Setback
Initial Setback Distance
20 feet on narrow street
15 on wide street
Building Height Within Initial Setback Distance = 85 feet or 6 stories whichever is less
Sky Exposure Plane Vertical to Horizontal
Narrow Street Sky Exposure Plane = 2.7 to 1
Wide Street Sky Exposure Plane = 5.6 to 1
C6-2 Alternate Height And Setback
Alternate height and setback regulations can apply if you provide open space for the entire length of the front lot line.
Depth Of Optional Front Yard
15 feet on narrow street
10 on wide street
Sky Exposure Plane Height Above Street Line = 85 feet
Sky Exposure Plane Vertical to Horizontal
Narrow Street Sky Exposure Plane = 3.7 to 1
Wide Street Sky Exposure Plane = 7.6 to 1
NYC Zoning
As an architect I study zoning very closely. NYC Zoning is complicated and quite involved. In this article we reviewed some of the basic Zoning Codes with regards to commercial zoning district C6-2. This analysis does not assume to cover every possible issue and condition, but provide a general overview. This post does not substitute the NYC Zoning Resolution.
Thank You for reading our Blog Post on C6-2 Zoning in NYC.
I hope this was helpful. You can leave questions or comments below. If you want to discuss a specific project with an architect you can contact us directly.
Contact Fontan Architecture
This post was written by Jorge Fontan AIA a Registered Architect and owner of New York City architecture firm Fontan Architecture. Jorge Fontan has earned 3 degrees in the study of architecture including two degrees from the City University of New York and a Masters Degree in Advanced Architectural Design from Columbia University. Jorge has a background in construction and has been practicing architecture for 20 years where he has designed renovations and new developments of various building types.