C4-5A Zoning NYC

by | Last updated Jul 12, 2020 | NYC Zoning

C4-5A Zoning is a General Commercial Contextual Zoning district in NYC. In C4-5A you can build a variety of commercial building uses, community facilities, and residential buildings. C4-5A has a residential equivalent of R7A a Contextual Zone.

The C4-5A Zoning District is a contextual sub district of C4 Zoning and C4-5 Zoning in NYC a commercial zoning district with optional residential use. Zoning districts that end with a letter are usually contextual zoning districts. Contextual Zoning Districts are required to comply with the Quality Housing Program for residential use. Commercial Buildings in Contextual Zoning have some Quality Housing Regulation applied to them as well specifically height and setback requirements.

 

C4-5 Zoning Districts:

C4-5A Residential Equivalent:

  • R7A

 

C4-5A Zoning Regulations

The C4-5A Zoning District has normally commercial and residential uses. C4-5A Zoning is mapped in a small area of Manhattan. The commercial uses are usually department stores, retail, entertainment, offices, and other commercial uses.

 

C4-5A Residential Equivalent

Most Commercial Zoning districts have a Residential Equivalent. This equivalent is the Residential Zoning you would comply with when developing a residential building or mixed use building. The residential equivalent for C4-5A is R7A Zoning.

 

Mixed Use Building C4-5A

You can develop a mixed use building with commercial and residential zoning. In this case you would apply the requirements of C4-5A and R7A in designing a mixed use building.

 

C4-5A Zoning Specifications

C4-5A Commercial Floor Area Ratio (FAR):

Floor Area Ratio determines the floor area that can be built on the property.

FAR =  4

The FAR is for Commercial Floor Area, residential use usually differs from Commercial.

C4-5A Community Facility Floor area Ratio

FAR =  4

This FAR applies to buildings with both commercial and community facility use.

Yard Requirements for Commercial Use in C4-5A

Side Yards

Side Yards are not required, but if side yards are provided they must comply with the following:

At minimum 8 feet in width or

At minimum 5 feet in width with an average width of 8 feet.

Some special circumstances will require side yards.

Rear Yard

20 Foot rear yard required

C4-5A Building Height and Setbacks

The building height and setbacks of commercial contextual districts are governed by the residential equivalent height and setback requirements for the Quality Housing Program.

 

NYC Zoning

As an architect I study zoning very closely. NYC Zoning is complicated and quite involved. In this article we reviewed some of the basic Zoning Codes with regards to commercial zoning district C4-5A. This analysis does not assume to cover every possible issue and condition, but provide a general overview of the zoning codes.

 


Thank You for reading our Blog Post on C4-5A Zoning in NYC.

I hope this was helpful. You can leave questions or comments below. If you want to discuss a specific project with an architect contact us directly.

 

Contact Fontan Architecture

 

Jorge Fontan

Jorge Fontan

This post was written by Jorge Fontan AIA a Registered Architect and owner of New York City architecture firm Fontan Architecture. Jorge Fontan has earned 3 degrees in the study of architecture including two degrees from the City University of New York and a Masters Degree in Advanced Architectural Design from Columbia University. Jorge has a background in construction and has been practicing architecture for 20 years where he has designed renovations and new developments of various building types.