C4-4 Zoning is a General Commercial Zoning district in NYC. In C4-4 you can build a variety of commercial building uses, community facilities, and residential buildings.
The C4-4 Zoning District is a sub district of C4 Zoning in NYC.
C4-4 Zoning Districts:
C4-4 Residential Equivalent:
- R7-2
C4-4 Zoning Regulations
The C4-4 zoning district is a General Commercial Zoning District with residential and commercial uses. These are mapped in The Bronx, Queens, and Upper Manhattan. C4-4 has a wide range of commercial uses.
C4-4 Residential Equivalent
Most Commercial Zoning districts have a Residential Equivalent. This means you can develop a residential building within the commercial zoning district. You follow the residential equivalent zoning requirements in the case of a residential development. The residential equivalent for C4-4 is R7-2 Zoning.
Mixed Use Building
You can develop a mixed use building with commercial and residential zoning. In this case you would apply the requirements of C4-4 and R7-2 in designing the building.
C4-4 Zoning Specifications
C4-4 Commercial Floor Area Ratio (FAR):
Floor Area Ratio determines the floor area that can be built on the property.
FAR = 3.4
The FAR is for Commercial Floor Area. Residential FAR usually differs from Commercial.
C4-3 Community Facility Floor area Ratio
FAR = 6.5
Sometimes the FAR is higher for community facilities as it is in this case.
Yard Requirements for Commercial Use in C4-4
Side Yards
Side Yards are not required, but if side yards are provided they must comply with the following:
At minimum 8 feet in width or
At minimum 5 feet in width with an average width of 8 feet.
Some special circumstances will require side yards.
Rear Yard
20 Foot rear yard required
C4-4 Height And Setback
Initial Setback Distance
20 feet on narrow street
15 on wide street
Building Height Within Initial Setback Distance = 60 feet or 4 stories whichever is less
Sky Exposure Plane Vertical to Horizontal
Narrow Street Sky Exposure Plane = 2.7 to 1
Wide Street Sky Exposure Plane = 5.6 to 1
C4-4 Alternate Height And Setback
Alternate height and setback regulations can apply if you provide open space for the entire length of the front lot line.
Depth Of Optional Front Yard
15 feet on narrow street
10 on wide street
Sky Exposure Plane Height Above Street Line = 60 feet
Sky Exposure Plane Vertical to Horizontal
Narrow Street Sky Exposure Plane = 3.7 to 1
Wide Street Sky Exposure Plane = 7.6 to 1
NYC Zoning
As an architect I study zoning very closely. NYC Zoning is complicated and quite involved. In this article we reviewed some of the basic Zoning Codes with regards to commercial zoning district C4-4. This analysis does not assume to cover every possible issue and condition, but provide a general overview. This post does not substitute the NYC Zoning Resolution.
Thank You for reading our Blog Post on C4-4 Zoning in NYC.
I hope this was helpful. You can leave questions or comments below. If you want to discuss a specific project with an architect you can contact us directly.
Contact Fontan Architecture
This post was written by Jorge Fontan AIA a Registered Architect and owner of New York City architecture firm Fontan Architecture. Jorge Fontan has earned 3 degrees in the study of architecture including two degrees from the City University of New York and a Masters Degree in Advanced Architectural Design from Columbia University. Jorge has a background in construction and has been practicing architecture for 20 years where he has designed renovations and new developments of various building types.